Voice Evacuation Systems

The SX-2100AO is an audio output of the matrix system and can be mounted in an EIA equipment rack (2 U size). Multiple units can be decentralized in a whole system. It is equipped with eight audio outputs, and two inputs can be mixed and output. It is also equipped with eight control inputs, and eight control outputs. The SX-2100AO receives audio signals from the audio input unit via digital transmission, but an analog audio input function (1 channel) enables simultaneous all-zone calls for use in emergency situations. Audio output levels are indicated on the level meters provided for each output channel. Volumes can be adjusted for each channel using the volume controls on the front panel or the SX-2000 software. The volume controls can be locked. Any output channel can be monitored using the internal speaker. Two channels of local audio inputs with control inputs are provided as the dedicated audio inputs. Its functions include an amplifier switching function that automatically switches the power amplifier to the standby amplifier if the power amplifier fails, and a surveillance function that self-diagnoses the speaker lines. Equipped with two channels of interfaces for connecting to the Emergency Power Supply units, making it possible to configure the system to operate during a power failure. One control IN/OUT interface allows the number of control inputs and outputs to be increased. The SX-2100AO has two power inputs and can support a dual-redundant power supply system.
| Specification | |
|---|---|
| Power Source | Usable power supply unit: VX-200PS 24V DC (operational range: 20V – 40V DC) Two power inputs construction enables dual- redundant power supply. |
| Current Consumption | Under 1.2A (when operated on the voltage where the current flows most) Under 0.79A (when operated on 24V DC) Note: But except current consumption of the external equipment of which power is supplied from the unit. |
| Indication | 18 alphanumeric characters, Level indication (8 outputs, monitor), Status indicators, Power indicator, Standby indicator, CPU |
| OFF indicator | |
| Operation | Function button, Output level control, Monitor speaker volume control, ON/OFF switch, Operation button |
| Audio Output | 8 outputs and standby AMP, 0 dB*, suitable load: 600 Ω or above, electronically-balanced, RJ45 Connector |
| monitoring possible using built-in speaker | |
| Audio Output Characteristic | Frequency response: 20 – 20,000Hz Sampling frequency: 48kHz D/A converter: 24 bit |
| Emergency Line Input | Emergency signals switched and sent to Input 1 (H, C, E) by relay removable terminal block (3 pins), Emergency audio input is connected to all outputs, when the power or an emergency cutoff 24V signal is cut off. |
| Emergency-Cutoff 24V Input | 1 input, input current: under 5mA, removable terminal block (2 pins), cancellation possible using DIP switch |
| SX Link | |
| Network I/F | 2 100 BASE-TX circuits, RJ45 connector, decentralized installation possible |
| Connection Cable/Device | Shielded Category 5 twisted pair cable for LAN (CAT5-STP) To be connected via the switching hub specified by TOA Note: This network must be made physically independent from other LAN. |
| Maximum Cable Distance | 100m (between this unit and a switching hub) |
| Analog Link | |
| Input/Output Connector | Input: 1 input, RJ45 connector Output: 1 output, RJ45 connector |
| Connection Cable | Shielded Category 5 twisted pair cable for LAN (CAT5-STP)(1 pair of audio wire + 1 pair of CPU OFF + 1 pair of control wire (system reset/standby) + 1 pair of connection check wire) |
| Maximum Cable Distance | Total length of analog audio link: 800m |
| Control Input | 8 inputs, no-voltage make contact input, open voltage 40V DC, short-circuit current: 2mA, photo coupler input, removable terminal block (6 pins) |
| Control Output | 8 outputs, C contact, no-voltage make contact output, relay contact output (withstand voltage: 40V DC, control current: 2 – 300mA), removable terminal block (6 pins) |
| Operating Temperature | 0°C to +40°C |
| Operating Humidity | 35% to 80% RH (no condensation) |
| Finish | Panel: Aluminum, black, alumite, Case: Surface-treated steel plate |
| Dimensions | 482 (W) × 88.4 (H) × 349 (D)mm |
| Weight | 6.2kg |
| Accessory | Removable terminal plug (12 pins) × 2, Removable terminal plug (6 pins) × 8, Removable terminal plug (4 pins) × 1, Removable terminal plug (3 pins) × 1, Removable terminal plug (2 pins) × 1, Rack mounting screw × 4 |
| Option | Line transformer: IT-450 |
VP-2064
VP-2064 (60 W-by-4 channels)
Power Amplifier uses the VP-200VX or VP-200VX-BGM Power Amplifier Input Module per channel.
VP-2241
VP-2241 (240 W-by-1 channel)
Power Amplifier uses the VP-200VX or VP-200VX-BGM Power Amplifier Input Module per channel.
VP-2421
VP-2421 (420 W-by-1 channel)
Power Amplifier uses the VP-200VX or VP-200VX-BGM Power Amplifier Input Module per channel.
SX-2000AO
The SX-2000AO is an audio output of the matrix system and can be mounted in an EIA equipment rack (2 U size). Multiple units can be decentralized in a whole system. It is equipped with eight audio outputs, and two inputs can be mixed and output. It is also equipped with eight control inputs, and eight control outputs. The SX-2000AO receives audio signals from the audio input unit via digital transmission, but an analog audio input function (1 channel) enables simultaneous all-zone calls for use in emergency situations. Audio output levels are indicated on the level meters provided for each output channel. Volumes can be adjusted for each channel using the volume controls on the front panel or the SX-2000 software. The volume controls can be locked. Any output channel can be monitored using the internal speaker. Two channels of local audio inputs with control inputs are provided as the dedicated audio inputs. Its functions include an amplifier switching function that automatically switches the power amplifier to the standby amplifier if the power amplifier fails, and a surveillance function that self-diagnoses the speaker lines. Equipped with two channels of interfaces for connecting to the Emergency Power Supply units, making it possible to configure the system to operate during a power failure. One control IN/OUT interface allows the number of control inputs and outputs to be increased. The SX-2100AO has two power inputs and can support a dual-redundant power supply system.
SX-2000SM
SX-2000SM can be used in combination with an optional audio input unit, audio output unit, and remote microphone of the SX-2000 Series to make up a complete matrix system and can perform audio signal routing and priority control for the entire system. The SX-2000SM itself is equipped with 8 control inputs, 8 control outputs, failure status outputs, failure data inputs/switches, access indicators mode indicators and failure indicators enabling a wide rage of controls and status monitoring. Each control can be performed by way of a CF card inserted into the SX-2000SM unit. Operations of the entire system can be recorded and their contents stored on a CF card as an operation log.
The SX-2000SM also features two power inputs making possible the creation of a dualredundant power system.
SX-2100AI
The SX-2100AI is an audio input of the matrix system and can be mounted in an EIA equipment rack (2U size). Multiple units can be decentralized in a whole system. It features modular construction that allows it to handle from two to eight inputs per unit. Audio signals are transmitted digitally to the audio output unit, but an analog audio output function (1 channel) enables simultaneous all-zone calls for use in emergency situations. Audio input levels are indicated on the level meters provided for each input channel. Volumes can be adjusted for each channel using the volume controls on the front panel or the SX-2000 software. The volume controls can be locked. Any input channel can be monitored using the internal speaker. It is also equipped with 16 control inputs, and 16 control outputs. It is equipped with two power inputs, allowing for a redundant power system.






Download now SX-2000 Firmware.zip
Download now SX-2000_LEAF_E.pdf